Solution
Cold chain temperature monitoring in transport
Load temperature measured every few dozen seconds and stored next to the vehicle's position, with a report after every run. For reefers, frozen bodies and insulated vans.
What actually has to be documented
For quick-frozen food the requirements are specific. Commission Regulation (EC) No 37/2005 says in Article 2(1) that means of transport, warehousing and storage must be fitted with suitable recording instruments to monitor, at frequent and regular intervals, the air temperature the food is subjected to. Not at loading and unloading – at frequent and regular intervals throughout. Article 2(2) adds that from 1 January 2006 the instruments must comply with EN 12830, EN 13485 and EN 13486, and that the operator keeps the documents proving it. Article 2(3) requires the records to be dated and kept for at least one year, or longer depending on the nature and shelf life of the food.
The temperature itself comes from Directive 89/108/EEC: after thermal stabilisation it must be stable and maintained at all points in the product at −18 °C or lower, with brief upward fluctuations of no more than 3 °C during transport and local distribution.
One exception is worth remembering, because it surprises producers. Ice cream and other edible ices are not quick-frozen foodstuffs for the purposes of Directive 89/108/EEC – Article 1(2) says so in as many words. That does not mean you may carry them warm. The general rules of Regulation (EC) No 852/2004 still apply: Annex II Chapter IV point 7 requires conveyances and containers to be capable of maintaining appropriate temperatures and to allow those temperatures to be monitored, and Annex II Chapter IX point 5 states that the cold chain is not to be interrupted. The target temperature is set by the producer in its own HACCP plan. The ATP agreement names −20 °C for ice cream.
Why two readings on a delivery note are not enough
Documentation in a small operation usually means a thermometer at the loading bay and a second reading at the drop, written by hand on the delivery note. The problem shows up with the first complaint. The customer says the goods arrived soft, and two numbers from two moments say nothing about the hours in between. Nobody knows whether the fridge unit stood idle for half an hour, or how long the van waited on the bay.
Inspections work the same way. The inspector does not ask about today's run; they ask for the records from the past months. The free app that ships with a Bluetooth logger normally keeps one day of history, because the data sits in a phone rather than on a server.
How Trackomo collects the data
You fit a wireless sensor inside the load space – we use the ELA Blue PUCK T EN12830: range −40 to +85 °C, resolution 0.0625 °C, IP68 case, a lithium battery measured in years. The sensor broadcasts its reading over Bluetooth Low Energy. A Teltonika tracker in the cab receives it and sends it to our server in the same data packet as the coordinates, the speed, and the ignition state.
One packet rather than two systems lined up on timestamps, and everything else follows from that. Every temperature reading has a place on the map, so a spike on the chart can be tied to a specific stop or a specific drop. Up to four sensors can be paired to one vehicle: front and rear of the body, or two compartments with different thresholds.
You pick the tracker to suit the body. The FMC003 plugs into the OBD socket and is ready in minutes; for the full set of vehicle data it needs firmware 03.28.03.Rev.94 or newer. The FMC130 is wired: inputs for probes and ignition cut-off – the choice for reefers with a fridge unit and for bodies with no diagnostic socket.
Alerts that do not cry wolf
The usual reason people switch temperature alerts off is false alarms on every delivery. Seven minutes of unloading in August lifts the reading by several degrees and the system starts shouting, although nothing went wrong.
So an alert in Trackomo has two parameters: a threshold and the minimum time it has to be exceeded. You set −15 °C and ten minutes, say. Unloading triggers nothing, but a fridge unit that has stopped holding does – and it does so before the goods are lost. Every breach, including the short ones, still goes into the report with its duration and its location.
- an upper and a lower threshold per sensor
- a minimum breach time, to filter out deliveries
- push notification, email, or both
- separate alerts for a sensor going silent and for a low sensor battery
- alerts muted for one vehicle while it is in the workshop
A report you can pass on
The daily report goes out by email in the morning and covers the previous day: a temperature chart with the threshold drawn on it, a measurement table with dates and times, and a list of breaches with their duration. The same PDF is what you show an inspector and what you send to a customer asking about the conditions their pallet travelled in. A report for a single run or a chosen date range is generated on demand, as PDF or CSV.
We keep readings and routes for a year, the period Article 2(3) of Regulation 37/2005 asks for. Where the shelf life of the goods runs longer, download the reports to your own disk before the year is out.
What this system will not do
- It does not replace sensor calibration. An EN 13486 certificate comes from the sensor manufacturer on request – we display readings, we do not certify their accuracy.
- It does not decide whether goods are still saleable after a break in cooling. That call belongs to whoever is responsible for food safety in your business.
- It does not measure the core temperature of the product. A sensor in the load space measures air, which is what Regulation 37/2005 asks for.
- It will not email a report until you name the recipients and the hour. You set that once, in the panel.
Questions we get most often
How many sensors do I need per vehicle?
For a single compartment, one, fitted at its warmest point – usually near the doors rather than at the evaporator outlet. For a body split into zones, one per zone. The limit is four per vehicle.
Do I need internet in the vehicle?
The tracker has its own SIM and sends data over the mobile network. With no coverage it buffers readings and uploads them once coverage returns, so the report has no gap.
How long does fitting take?
An FMC003 in the OBD socket plus sticking the sensor in place is about fifteen minutes per vehicle. The FMC130 needs an auto electrician, usually one visit for several vehicles.
Can my customer see the data?
You can send them the PDF report or share a link with the vehicle's position and arrival time. The link does not show load temperature today – it shows position and ETA.
Related pages
Try it on your own vehicles
You set the account up yourself, without talking to us. The first 30 days cost nothing.